近年来居民小区配电室的数量增长快且设备情况较复杂,以致巡视效果不理想、缺陷和事故处理不及时,亟需建立一套智能化的配电室监控系统。按照实用性、统一性、分层和模块化设计等原则,提出了"三层八纵"的建设方案,即由远方层、中间层和本地层组成层次结构,构建门禁、电气量遥测、电气量遥信、温湿度监测、视频、遥控遥调、直流和继电保护8个子系统。该方案层次结构清楚、功能模块化且易于扩展,具有较强的实用性。
Abstract:The number of power distribution room in residential districts is growing quickly in recent years. Conditions of equipment in power distribution rooms are complex, and the patrol effect result is non-ideal, the defect and accident treatment is non-timely. So a smart monitoring system of power distribution room is needed as soon as possible. According to principles of practicality, unity, hierarchical and modular design, a scheme of " three levels and eight verticals" is proposed, which is composed by remote layer, intermediate layer and local layer. It contains eight subsystems, namely,access control, electrical quantities telemetry, remote communication of electrical quantities, temperature and humidity monitor, video, remote control and adjustment of electrical quantities, DC and relay protection system. The scheme has a clear hierarchical structure, function modularization, easily expandable feature and strong practicability.
[1]刘沛骞,陈俊杰,王成文,等.基于GPRS的配电变压器实时监控一体化系统[J].电网技术,2005,29(6):82-84.
[2]何为,蔡梅园,刘细亮.基于GSM通信的配电变压器远程监控系统设计[J].电力系统保护与控制,2009,37(1):83-86.
[3]杨艳华,苏红军,周永录.基于PLC和Modbus的配电室现场环境监控系统设计[J].云南大学学报(自然科学版),2013,35(S2):211-216.
[4]严冬,龙国强,王平,等.基于Modbus协议的配电室环境监测系统设计[J].四川大学学报(自然科学版)2015,52(3):538-546.
[5]刘柳,王东兴.基于μC/OS-II的配电室监控终端的研究[J].微计算机信息,2007,23(17):68-72.
[6]刘春玲,张焕生,郝国芬,等.基于VPN技术的供配电监控系统的设计[J].电源技术,2004,38(11):2 180-2 181.
[7]何方,吕成军.高压开关配电室SF6环境监测系统的设计[J].仪表技术与传感器,2007(3):35-37.
[8]刘花锋,庞士信,徐洪,等.基于ARM的高压配电室SF6监测系统设计[J].仪表技术与传感器,2009(S1):418-419.
[9]张迎辉,邓松,陈素芳.基于CC-Link/LT总线技术的低压供配电监控系统设计[J].电力系统保护与控制,2009,37(9):129-134.
基本信息:
中图分类号:TM641
引用信息:
[1]吕平,向珉江,赵嫄,等.居民小区智能化配电室建设方案探讨[J].山东电力技术,2016,43(09):46-49.
2016-09-25
2016-09-25